ESP LOW-E MICRO-E INSULATION
PRODUCT CODES*: 4EMET (trimmed), 4EMES
PRODUCT DIMENSIONS & DESCRIPTION*
Double sided scrimless aluminum foil laminated to polyethylene foam ( .
Edges can be trimmed or with staple flange.
WIDTH**: 4’
LENGTH**: 125’ (stock size 4’width)
R-Value*** : R-10 down R-6 up R-7 horizontal
PERM RATING: ASTM E-96 0.008
FLAME AND SMOKE: ASTM E-84 Flame spread <25 Smoke developed <50
EMITTANCE: 0.03
®
* This label refers to the Micro-E line of insulation products supplied by ESP, Inc. and includes information on different widths and attachment
®
features of the Micro-E line. For information on specific product purchased refer to thermal label affixed to the roll of insulation
** Additional widths and lengths are available upon request and approval by ESP, Inc.
*** R-value results are obtained from ASTM C236.
®
(staple flange)
1/8” nominal thickness)
ASTM C-1371
Environmentally Safe Products, Inc.
313 W. Golden Ln. New Oxford, PA 17350
Toll Free: 1-800-289-5693 Fax: 717-624-7089
www low-e.com E-mail: [email protected]
®
Micro-E Insulation
Reduces your carbon footprint.
E
S
P
®
Scan code to see
Install Guide
®
ESP Micro-E is a versatile product for many applications and industries.
NOTE: Do not allow product to become damp or wet while rolled in sealed bag
Do not set product directly on wet or uncured concrete.
®
WARNING: Although ESP LOW-E Insulation Products are all fire tested to ASTM and/or NFPA standards; it is
recommended that they or any insulation material should not be exposed to open flame or other
ignition sources of sufficient intensity during shipment, storage or installation.
CAUTION: Aluminum is an electrical conductor. Please use caution when working around electrical sources
including overhead power lines. Carefully inspect electrical junction boxes and check for frayed
wires before beginning installation
Specific R-values for specific applications can be obtained from Install Guide at www.low-e.com or by contacting ESP, Inc. at 1-800-289-5693
R means resistance to heat flow. The higher the R-value, the greater the insulating power.To get the marked R-Value, it is essential that this insulation be
installed properly. If you do it yourself, get instructions and follow them carefully. Instructions do not come with this package.To obtain installation instructions
visit www.low-e.com or call 1-800-289-5693. Like a radiant barrier, Low-E products also block 97% of radiant heat.
copyright©espjul1.2012
ESP, Inc strives to provide the most accurate R-value data possible.
The R-values set forth in this document are the reflection of a
combination of industry standard testing and conscientious calculation.
However, these numbers, even within specific applications, can fluctuate
due to the multiple variables that influence R-value."