ESP LOW-E TAB INSULATION
PRODUCT CODES: 16EFEC, 24EFEC, 18EFEC
PRODUCT DIMENSIONS & DESCRIPTION
Double sided scrimless aluminum foil laminated to polyethylene foam
WIDTH: 16”, 24”, 18” respectively
LENGTH: 125’ (16” & 24”widths) 100’ (18”width)
R-Value* : R-11 down R-7.55 up R-7.75 horizontal
PERM RATING: ASTM E-96 0.008
FLAME AND SMOKE: ASTM E-84 Flame spread <25 Smoke developed <50
EMITTANCE: 0.03
* R-value results are obtained from ASTM C236. R-values for tab materials can be higher or lower depending upon
application. Specific R-values for specific applications can be obtained from Install Guide at www.low-e.com or
by contacting ESP, Inc. at 1-800-289-5693
(1/4” nominal thickness)
ASTM C-1371
Environmentally Safe Products, Inc.
313 W. Golden Ln. New Oxford, PA 17350
Toll Free: 1-800-289-5693 Fax: 717-624-7089
www low-e.com E-mail: [email protected]
Tab Insulation
Reduces your carbon footprint.
E
S
P
®
Scan Code To
See Install Guide
copyright©espaug1.2011
NOTE: Do not allow product to become damp or wet while rolled in sealed bag
Do not set product directly on wet or uncured concrete.
®
WARNING: Although ESP LOW-E Insulation Products are all fire tested to ASTM and/or NFPA standards; it is
recommended that they or any insulation material should not be exposed to open flame or other
ignition sources of sufficient intensity during shipment, storage or installation.
CAUTION:
Aluminum is an electrical conductor. Please use caution when working around electrical
sources including overhead power lines. Carefully inspect electrical junction boxes and
check frayed wires before beginning installation
®
Note: ESP Low-E Tab Material is designed for use in stud cavities, joists, and truss/rafter applications.
R means resistance to heat flow. The higher the R-value, the greater the insulating power.To get the marked R-Value, it is essential that this insulation be
installed properly. If you do it yourself, get instructions and follow them carefully. Instructions do not come with this package.To obtain installation instructions
visit www.low-e.com or call 1-800-289-5693. Like a radiant barrier, Low-E products also block 97% of radiant heat.
ESP, Inc strives to provide the most accurate R-value data possible. The R-values set forth in this document are the reflection of a combination of industry standard
testing and conscientious calculation. However, these numbers, even within specific applications, can fluctuate due to the multiple variables that influence R-value."
16.
YOUR EVERYDAY INSULATION SOLUTION
Vedere la pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 24

Commenti su questo manuale

Nessun commento